Paxos Advance
Product Info:
Information:
Paxos is the redundant, motorized lock for safes and vaults when it comes to providing maximum reliability, ease of use, programming and installation. Over a course of millions of operating hours, Paxos has proven technology and reliability time and time again.
The next generation Paxos advance is the consistent and logical advancement of this reliable and proven technology. It combines highest reliability with user-friendliness and now also allows for a simple connection of multiple lock units and input units in one locking system.
Comprehensive functions are already comprised in the basic version and meet highest customer demands.
Codes:
100 codes per lock
with ID+PIN:
1 master code
2 opening codes
97 codes with individually scalable opening and access authorizations
Code aging, individual name for each code
with PIN:
1 master code
1 mutation code
1 time code
2 AND codes
95 opening codes, single or dual opening
with multiple lock units:
Parallel mode
Partial locking
Approvals / Certificates:
EN 1300 B,C
VdS electronic high security lock, class 2, 3
VdS blocking element for IDS class C
VdS strike plate contact for IDS class C
VdS duress alarm trigger for IDS class C
Features:
Alarm connection:
Pre-condition: I/O-Box Outputs:
8 free selectable outputs, polarity NO/NC selectable.
For instance for monitoring of lock bolt and bolt work position, duress alarm, battery status, tamper status.
Inputs:
8 free selectable inputs, polarity NO/NC selectable., tamper-monitored if desired.
For instance for remote disable, time lock interruption, time delay override.
Power Supply:
Battery power supply
Rechargeable battery pack
Mains connection
UPS connection
Automatic recognition oft he type of power supply. Automatic change-over to alternative power supply in case of power failure.
Input unit:
Black plastic housing
Silicon rubber keypad or dial knob
Integrated battery compartment
Graphic LC display with adjustable background illumination and contrast
Full text user guidance
Operator selectable display language
Buzzer
Integrated USB interface for programming and audit
Combination of multiple input units in one system
Lock unit:
Bi-directional, motorized dead bolt
30 N moving force in both directions
Adjustable bolt travel 8.7, 12, 14, 15 mm
Bolt with 2 threads M4 and centric thread M5
Standard footprint
Standard housing dimensions
Combination of multiple lock units in one system, with main door locks and inner cabinet locks
Technical Data:
Lock unit:
Bi-directional, active full-redundant motor-bolt lock
Integrated evaluation and control electronics, contains code management and full time lock functions such as date and time, summer/winter-time changeover, weekly time lock program, holiday periods, partial locking and time lock override windows.
Suitable as first lock unit or as additional lock unit
Suitable as inner cabinet lock unit
Keypad input unit:
black plastic housing with Silicon rubber keypad
graphic LC display with adjustable background illumination and contrast
full text user guidance
operator selectable display language
buzzer
integrated USB interface for programming and audit
combination of multiple input units in one system
pre-condition for: VdS class 2, EN 1300 class B
Dial knob input unit:
black plastic housing
graphic LC display with adjustable background illumination and contrast
lateral limitation of visibility angle
full text user guidance
spy-proof code-entry
operator selectable display language
buzzer
integrated USB interface for programming and audit
combination of multiple input units in one system
pre-condition for: VdS class 3, EN 1300 class C
Options:
I/O Box
Built-in terminals for external signal connection
The I/O-Box is pre-condition to connect
– external power such as a power supply, UPS
– signals from/to peripheral devices such as an alarm panel, remote disable actuator, etc.
Blocking element VdS
Upgrade kit (cover) for combined use as a numeric combination code lock and as a blocking element in the controlled sequence for arming a danger detection system.
Programming Software AS 354
For configuration of the locking system, programming of the settings and to read-out the audit. Connection through USB interface in input unit.
Software package including CD-ROM with software and documentation, USB cable, license dongle.
Runs on Microsoft® Windows® operating systems. Operator selectable language.
Audit Software AS 356
To read-out the audit.
Connection through USB interface in input unit.
Software package including CD-ROM with software and documentation, USB cable, license dongle.
Runs on Microsoft® Windows® operating systems. Operator selectable language.
Functionality:
Code functions:
Code format PIN or ID+PIN
Individually scalable opening and access rights (code profiles)
Code aging
Individual name for each code
Dual mode per lock unit (AND codes, dual mode)
User-related dual mode (user groups)
Parallel mode1)
Wrong trial lock-out
Duress code (silent alarm)
Reset function (shelve)
Time lock functions:
Normal time delay
Duress time delay
Confirmation window
Day-time related time delays
User-related time delays
Non-return time delay
Monitoring of lock open period
Fully automatic DLST (summer/winter time changeover)
Holiday periods
Yearly repeating holiday periods
Weekly time locks
Immediate locking
Time lock override by pre-programmable override windows
Time lock override by code
Time lock interruption by input signal
Time lock interruption by internal push-button
Partial locking periods (day/night mode) 1)
Time delay for day lock in partial locking 1)
Other functions:
Multi lock operation
Control of inner cabinet locks
Automatic or manual locking
Tamper monitoring
Low voltage detection
Battery status display
Opening counter
Error diagnosis, recognition and display
Programming and audit over USB/computer 2)
Audit in plain text, with search and filter functions 2)
Free programmable in/outputs 3